Reference segment
|
Segment, the pier is connected to. The pier is dependent on this segment.
|
Segment point
|
Segment point of the reference segment.
Default: 1st segment point
|
Part of segment point
|
Part of the segment point of the reference segment.
Default: 1st part
|
Radio buttons Before / After
|
FE-cross section, that defines the geometrical position of the cable.
Default: "After"
|
Connection point
|
The connection point has to be defined previously at the cross section, that is assigned to the segment point of the reference segment. The geometrical position of the cable is unique defined by the segment point, the option "before/after" and this point at the cross section.
|
Cable parameters
|
Input of the element and node numbers, the material and the cross section area. It is possible to define a cross section for cables.
|
Stationing
|
The Stationing is defined relatively between 0 and 1. The 1st segment point is situated at station 0.0 and the last one at station 1.0.
Note: Both points are not able to be deleted in the segment point list.
Between these points, further points may exist to subdivide the cable into different elements.
|
Copy of cables
|
The copy function can be used very efficiently, if one cable has been defined completely (inclusive numbering, material, ...). Afterward, this cable may be copied several times. All properties of the source cable will be transferred to the new generated ones.
|